summaryrefslogtreecommitdiff
path: root/doc
diff options
context:
space:
mode:
authoryvesf <yvesf@d0e8fea9-7529-0410-93fb-d39fd5b9c1dd>2010-04-24 13:02:22 +0000
committeryvesf <yvesf@d0e8fea9-7529-0410-93fb-d39fd5b9c1dd>2010-04-24 13:02:22 +0000
commit7a1542162fe2c2f06f808b3b628e028576a28114 (patch)
tree0631bf1ce5037e38a043d6b071aca2c969b1f6e9 /doc
parent697dee0c94d256f1b858748753264c8731fa55f1 (diff)
downloadebus-alt-7a1542162fe2c2f06f808b3b628e028576a28114.tar.gz
ebus-alt-7a1542162fe2c2f06f808b3b628e028576a28114.zip
spec up
git-svn-id: http://10.2.2.13/svn/common/ebus@1667 d0e8fea9-7529-0410-93fb-d39fd5b9c1dd
Diffstat (limited to 'doc')
-rw-r--r--doc/ebus_specification.html398
-rw-r--r--doc/ebus_specification.html.xslt53
2 files changed, 375 insertions, 76 deletions
diff --git a/doc/ebus_specification.html b/doc/ebus_specification.html
index 0969fe8..fbdd101 100644
--- a/doc/ebus_specification.html
+++ b/doc/ebus_specification.html
@@ -1,21 +1,62 @@
<html>
-<head><meta http-equiv="Content-Type" content="text/html; charset=UTF-8"></head>
+<head>
+<meta http-equiv="Content-Type" content="text/html; charset=UTF-8">
+<style type="text/css">
+ table {
+ border: 1px solid gray;
+ width: 100%;
+ }
+ table td {
+ border-left: 1px dotted gray;
+ border-right: 1px dotted gray;
+ }
+
+ table th {
+ border: 1px dotted gray;
+ }
+ </style>
+</head>
<body>
<h2>Ebus Geräte</h2>
-<table class="ebus_devices">
+<table class="devices">
<tr>
<th>Adresse</th>
<th>Gerät</th>
<th>Typ</th>
</tr>
<tr>
+<td>0x00</td>
+<td>PC/Modem</td>
+<td>master</td>
+</tr>
+<tr>
<td>0x03</td>
-<td>Feuerungsautomat</td>
+<td>Feuerungsautomat 2</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0x0f</td>
+<td>RC Clock Model</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0x07</td>
+<td>Unknown</td>
<td>master</td>
</tr>
<tr>
<td>0x10</td>
-<td>Heizungsregler 2</td>
+<td>Heizkreisregler 2</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0x11</td>
+<td>Bus Interface 1</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0x13</td>
+<td>Feuerungsautomat 2</td>
<td>master</td>
</tr>
<tr>
@@ -24,6 +65,16 @@
<td>master</td>
</tr>
<tr>
+<td>0x31</td>
+<td>Bus Interface 2</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0x33</td>
+<td>Feuerungsautomat 3</td>
+<td>master</td>
+</tr>
+<tr>
<td>0x70</td>
<td>Heizkreisregler 2</td>
<td>master</td>
@@ -34,6 +85,11 @@
<td>master</td>
</tr>
<tr>
+<td>0x73</td>
+<td>Feuerungsautomat 4</td>
+<td>master</td>
+</tr>
+<tr>
<td>0xf1</td>
<td>Heizkreisregler 10</td>
<td>master</td>
@@ -59,170 +115,388 @@
<td>slave</td>
</tr>
<tr>
+<td>0xf0</td>
+<td>Heizkreisregler 3</td>
+<td>master</td>
+</tr>
+<tr>
+<td>0xf3</td>
+<td>Feuerungsautomat 5</td>
+<td>master</td>
+</tr>
+<tr>
<td>0xfe</td>
<td>Broadcastadresse</td>
<td>broadcast</td>
</tr>
+<tr>
+<td>0xff</td>
+<td>PC</td>
+<td>master</td>
+</tr>
</table>
-<h2>Ebus Packete</h2>
-<table class="ebus_packets">
+<h2>Ebus Pakete</h2>
+<table class="packets">
<tr>
-<th>prim. command</th>
-<th>sec. command</th>
-<th>descript.</th>
-<th>fieldsr</th>
+<th>Primary Command</th>
+<th>Secondary Command</th>
+<th>Name</th>
+<th>Description</th>
</tr>
<tr>
<td>0x05</td>
<td>0x03</td>
+<td>betriebsdatenRegler1</td>
<td>Betriebsdaten des Feuerungsautomaten an den Regler Block1</td>
-<td><table><tr>
-<th>name</th>
-<th>typ</th>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
+<tr>
<th>offset</th>
-</tr></table></td>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
+</tr>
+<tr>
+<td>3</td>
+<td>byte</td>
+<td>stellgradKesselleistung</td>
+<td>Stellgrad Kesselleistung</td>
+</tr>
+<tr>
+<td>4</td>
+<td>data1c</td>
+<td>kesselTemperatur</td>
+<td>Kessel Temperatur</td>
+</tr>
+<tr>
+<td>4</td>
+<td>byte</td>
+<td>ruecklaufTemperatur</td>
+<td>Rücklauf Temperatur</td>
+</tr>
+<tr>
+<td>6</td>
+<td>byte</td>
+<td>boilerTemperatur</td>
+<td>Boiler Temperatur</td>
</tr>
<tr>
+<td>7</td>
+<td>byte</td>
+<td>aussenTemperatur</td>
+<td>Aussentemperatur</td>
+</tr>
+</table></td>
+</tr>
+<tr><td colspan="4"><hr></td></tr>
+<tr>
<td>0x05</td>
<td>0x07</td>
+<td>betriebsdatenFeuerungsautomat</td>
<td>Betriebsdaten des Reglers an den Feuerungsautomaten</td>
-<td><table>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
<tr>
-<th>name</th>
-<th>typ</th>
<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
</tr>
<tr>
-<td>betriebszustand</td>
-<td>byteEnum</td>
<td>0</td>
+<td>byteEnum</td>
+<td>betriebszustand</td>
+<td>
+ </td>
</tr>
<tr>
-<td>aktion</td>
-<td>byteEnum</td>
<td>1</td>
+<td>byteEnum</td>
+<td>aktion</td>
+<td>
+ </td>
</tr>
<tr>
-<td>kesselSollwertTemperatur</td>
-<td>data2c</td>
<td>2</td>
+<td>data2c</td>
+<td>kesselSollwertTemperatur</td>
+<td>Kessel Temperatur Sollwert</td>
</tr>
<tr>
-<td>kesselSollwertDruck</td>
-<td>data2b</td>
<td>4</td>
+<td>data2b</td>
+<td>kesselSollwertDruck</td>
+<td>Kesseldruck Sollwert</td>
</tr>
<tr>
-<td>stellgrad</td>
-<td>data1c</td>
<td>6</td>
+<td>data1c</td>
+<td>stellgrad</td>
+<td>Stellgrad</td>
</tr>
<tr>
-<td>brauchwasserSollwert</td>
-<td>data1c</td>
<td>7</td>
+<td>data1c</td>
+<td>brauchwasserSollwert</td>
+<td>Brauchwasser Sollwert</td>
</tr>
</table></td>
</tr>
+<tr><td colspan="4"><hr></td></tr>
<tr>
<td>0x07</td>
<td>0x00</td>
+<td>datumZeit</td>
<td>Datum/Zeit Meldung eines eBus Master</td>
-<td><table>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
<tr>
-<th>name</th>
-<th>typ</th>
<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
</tr>
<tr>
-<td>aussenTemperatur</td>
-<td>data2b</td>
<td>0</td>
+<td>data2b</td>
+<td>aussenTemperatur</td>
+<td>Aussentemperatur</td>
</tr>
<tr>
-<td>sekunden</td>
-<td>bcd</td>
<td>2</td>
+<td>bcd</td>
+<td>sekunden</td>
+<td>Sekunden</td>
</tr>
<tr>
-<td>minuten</td>
-<td>bcd</td>
<td>3</td>
+<td>bcd</td>
+<td>minuten</td>
+<td>Minuten</td>
</tr>
<tr>
-<td>stunden</td>
-<td>bcd</td>
<td>4</td>
+<td>bcd</td>
+<td>stunden</td>
+<td>Studen</td>
</tr>
<tr>
-<td>tag</td>
-<td>bcd</td>
<td>5</td>
+<td>bcd</td>
+<td>tag</td>
+<td>Tag</td>
</tr>
<tr>
-<td>monat</td>
-<td>bcd</td>
<td>6</td>
+<td>bcd</td>
+<td>monat</td>
+<td>Monat</td>
</tr>
<tr>
-<td>wochentag</td>
-<td>bcd</td>
<td>7</td>
+<td>bcd</td>
+<td>wochentag</td>
+<td>Wochentag</td>
</tr>
<tr>
-<td>jahr</td>
-<td>bcd</td>
<td>8</td>
+<td>bcd</td>
+<td>jahr</td>
+<td>Jahr</td>
</tr>
</table></td>
</tr>
+<tr><td colspan="4"><hr></td></tr>
<tr>
<td>0x08</td>
<td>0x00</td>
+<td>sollwertuebertragungRegler</td>
<td>Sollwertübertragung des Reglers an andere Regler</td>
-<td><table><tr>
-<th>name</th>
-<th>typ</th>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
+<tr>
<th>offset</th>
-</tr></table></td>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
+</tr>
+<tr>
+<td>0</td>
+<td>data2b</td>
+<td>TK_soll</td>
+<td>Kessel Sollwert in °C [1/256]</td>
</tr>
<tr>
+<td>2</td>
+<td>data2b</td>
+<td>TA_ist</td>
+<td>Aussentemperatur in °C [1/256]</td>
+</tr>
+<tr>
+<td>4</td>
+<td>data1b</td>
+<td>L_zwang</td>
+<td>Leistungszwang in %</td>
+</tr>
+<tr>
+<td>5</td>
+<td>bit</td>
+<td>Status</td>
+<td>Status</td>
+</tr>
+<tr>
+<td>6</td>
+<td>data2b</td>
+<td>TB_soll</td>
+<td>Brauchwassersollwert</td>
+</tr>
+</table></td>
+</tr>
+<tr><td colspan="4"><hr></td></tr>
+<tr>
<td>0x03</td>
<td>0x08</td>
+<td>brenstoffmengeLesen</td>
<td>Gesamtbrennstoffmenge Lesen</td>
-<td><table><tr>
-<th>name</th>
-<th>typ</th>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields"><tr>
<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
</tr></table></td>
</tr>
+<tr><td colspan="4"><hr></td></tr>
+<tr>
+<td>0x50</td>
+<td>0x14</td>
+<td>vorlauftemperatur</td>
+<td>Reversed: http://www.mikrocontroller.net/topic/91164#1070401</td>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
+<tr>
+<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
+</tr>
+<tr>
+<td>0</td>
+<td>data2b</td>
+<td>vorlauftemperaturIst</td>
+<td>Aktuelle Vorlauftemperatur Mischerkreis</td>
+</tr>
+<tr>
+<td>2</td>
+<td>data2b</td>
+<td>vorlauftemperaturSoll</td>
+<td>Soll Vorlaufteperatur Mischerkreis</td>
+</tr>
+</table></td>
+</tr>
+<tr><td colspan="4"><hr></td></tr>
<tr>
<td>0x50</td>
<td>0x17</td>
+<td>solarDaten</td>
<td>Solar Daten</td>
-<td><table>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
<tr>
-<th>name</th>
-<th>typ</th>
<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
</tr>
<tr>
-<td>solarPumpe</td>
-<td>bit</td>
<td>0</td>
+<td>bit</td>
+<td>solarPumpe</td>
+<td>Betriebszustand Solarpumpe</td>
</tr>
<tr>
+<td>2</td>
+<td>data2c</td>
<td>tempKollektor</td>
+<td>Wassertemperatur am Kollektor</td>
+</tr>
+<tr>
+<td>4</td>
<td>data2c</td>
+<td>tempWarmwasserSolar</td>
+<td>Warmwassertemperatur am Kollektor</td>
+</tr>
+</table></td>
+</tr>
+<tr><td colspan="4"><hr></td></tr>
+<tr>
+<td>0x50</td>
+<td>0x18</td>
+<td>solarDatenSumme</td>
+<td>Reversed siehe ebus-wiki</td>
+</tr>
+<tr>
+<td></td>
+<td colspan="3"><table class="fields">
+<tr>
+<th>offset</th>
+<th>typ</th>
+<th>name</th>
+<th>Description</th>
+</tr>
+<tr>
+<td>0</td>
+<td>data2b</td>
+<td>aktuelleLeistung</td>
+<td>Aktuelle Solarleistung</td>
+</tr>
+<tr>
<td>2</td>
+<td>word</td>
+<td>tagesertragLow</td>
+<td>Tagesertrag low</td>
</tr>
<tr>
-<td>tempWarmwasserSolar</td>
-<td>data2c</td>
<td>4</td>
+<td>word</td>
+<td>tagesertragHigh</td>
+<td>Tagesertrag high * 1000</td>
+</tr>
+<tr>
+<td>6</td>
+<td>word</td>
+<td>ertragssumme</td>
+<td>Ertragssumme</td>
+</tr>
+<tr>
+<td>8</td>
+<td>word</td>
+<td>ertragssummeT</td>
+<td>Ertragssumme T * 1000</td>
+</tr>
+<tr>
+<td>10</td>
+<td>word</td>
+<td>ertragssummeM</td>
+<td>Etragssumme M * 1000 * 1000</td>
</tr>
</table></td>
</tr>
+<tr><td colspan="4"><hr></td></tr>
</table>
</body>
</html>
diff --git a/doc/ebus_specification.html.xslt b/doc/ebus_specification.html.xslt
index 668d3ba..2743e5b 100644
--- a/doc/ebus_specification.html.xslt
+++ b/doc/ebus_specification.html.xslt
@@ -5,11 +5,25 @@ xmlns:xsl="http://www.w3.org/1999/XSL/Transform">
<xsl:template match="/">
<html>
<head>
- <meta http-equiv="Content-Type" content="text/html; charset=utf8" />
+ <meta http-equiv="Content-Type" content="text/html; charset=utf8"/>
+ <style type="text/css">
+ table {
+ border: 1px solid gray;
+ width: 100%;
+ }
+ table td {
+ border-left: 1px dotted gray;
+ border-right: 1px dotted gray;
+ }
+
+ table th {
+ border: 1px dotted gray;
+ }
+ </style>
</head>
<body>
<h2>Ebus Geräte</h2>
- <table class="ebus_devices">
+ <table class="devices">
<tr>
<th>Adresse</th>
<th>Gerät</th>
@@ -27,36 +41,47 @@ xmlns:xsl="http://www.w3.org/1999/XSL/Transform">
</xsl:for-each>
</table>
- <h2>Ebus Packete</h2>
- <table class="ebus_packets">
+ <h2>Ebus Pakete</h2>
+ <table class="packets">
<tr>
- <th>prim. command</th>
- <th>sec. command</th>
- <th>descript.</th>
- <th>fieldsr</th>
+ <th>Primary Command</th>
+ <th>Secondary Command</th>
+ <th>Name</th>
+ <th>Description</th>
</tr>
<xsl:for-each select="ebus/packets/packet">
<tr>
<td><xsl:value-of select="@primary"/></td>
<td><xsl:value-of select="@secondary"/></td>
+ <td><xsl:value-of select="@name"/></td>
<td><xsl:value-of select="@description"/></td>
- <td>
- <table>
+ </tr>
+ <tr>
+ <td/>
+ <td colspan="3">
+ <table class="fields">
<tr>
- <th>name</th>
- <th>typ</th>
<th>offset</th>
+ <th>typ</th>
+ <th>name</th>
+ <th>Description</th>
</tr>
<xsl:for-each select="fields/*">
<tr>
- <td><xsl:value-of select="@name"/></td>
- <td><xsl:value-of select="name()"/></td>
<td><xsl:value-of select="@offset"/></td>
+ <td><xsl:value-of select="name()"/></td>
+ <td><xsl:value-of select="@name"/></td>
+ <td><xsl:value-of select="text()"/></td>
</tr>
</xsl:for-each>
</table>
</td>
</tr>
+ <tr>
+ <td colspan="4">
+ <hr />
+ </td>
+ </tr>
</xsl:for-each>
</table>
</body>