#!micropython
print("Start main.py")
import os
import machine
import socket
import time
import micropython as mp
HOST = config['CONFIG_INFLUXDB_HOST']
PORT = config['CONFIG_INFLUXDB_PORT']
PATH = config['CONFIG_INFLUXDB_PATH']
H_REQUEST = bytes('POST /%s HTTP/1.1\r\n' % PATH, 'utf8')
H_HOST = bytes('Host: %s\r\n' % HOST, 'utf8')
H_CONTENT_TYPE = bytes('Content-Type: application/x-www-urlencoded\r\n', 'utf8')
H_CONTENT_LENGTH = bytes('Content-Length: %s\r\n', 'utf8')
H_CONNECTION = bytes('Connection: close\r\n', 'utf8')
H_NL = bytes('\r\n', 'utf8')
def post(data):
print('[%d] Send HTTP POST: %s. Response: ' % (time.ticks_ms(), data), end='')
addr = socket.getaddrinfo(HOST, PORT)[0][-1]
data = bytes(data, 'utf8')
s = socket.socket()
s.connect(addr)
s.send(H_REQUEST)
s.send(H_HOST)
s.send(H_CONTENT_TYPE)
s.send(H_CONTENT_LENGTH % len(data))
s.send(H_CONNECTION)
s.send(H_NL)
s.send(data)
first_data = s.recv(100)
if first_data:
line, *_ = first_data.split(b'\r\n')
print(line, end='')
while data:
data = s.recv(100)
s.close()
print('')
d4_total = 0
d4_count = 0
d1_total = 0
d1_count = 0
def update(t):
global d4_total, d4_count, d1_total, d1_count
d4 = d4_count
d1 = d1_count
post('stromzaehler3 d4_count=%d,d4_total=%d,d1_count=%d,d1_total=%d' % (
d4, d4_total, d1, d1_total))
d4_count -= d4
d1_count -= d1
timer1 = machine.Timer(-1)
timer1.init(period=10000, mode=machine.Timer.PERIODIC, callback=update)
def persist(t):
write_persistent_int("d4_total.txt", d4_total)
write_persistent_int("d1_total.txt", d1_total)
# Import
def cb_d4(p):
global d4_total, d4_count
v = p.value()
if v != 1: # skip rising edge
d4_total += 1
d4_count += 1
d4 = machine.Pin(2, machine.Pin.IN, pull=machine.Pin.PULL_UP)
d4.irq(handler=lambda p: mp.schedule(cb_d4, p))
# Export
def cb_d1(p):
global d1_total, d1_count
v = p.value()
if v != 1: # skip rising edge
d1_count += 1
d1_total += 1
d1 = machine.Pin(5, machine.Pin.IN)
d1.irq(handler=lambda p: mp.schedule(cb_d1, p))
# Pumpe
d3_last_value = 0
def cb_d3(p):
global d3_last_value
print('[%d] %s = %d' % (time.ticks_ms(), repr(p), p.value()))
v = 1 - p.value()
if v != d3_last_value:
post('stromzaehler3.Pumpe Status=%s' % v)
d3_last_value = v
d3 = machine.Pin(0, machine.Pin.IN, pull=machine.Pin.PULL_UP)
d3.irq(handler=lambda p: mp.schedule(cb_d3, p))
print("main.py finished")
|